I. Enable the Developer API

  • From the AXIS Camera Station computer, launch the AXIS Camera Station Service Control (Start>Programs>AXIS Camera Station> AXIS Camera Station Tools>Service Control).
  • Select the Developer API tab and check the Modify settings Under Settings, check the Enable Developer API box, take note of the Developer API port (50333) and Video port (50334), then click Save. ?

II. Install the IS Video Component

  • From the Symphony AC server, download the IS Video Component from Senstar website or click here.
  • Run the IS_Video_Setup.exe to install this IS Video component.

III. Adding the Axis Camera Station Driver

  • Launch Symphony AC.
  • Go to the Hardware Manager and unlock the module.
  • In the Hardware tree, right-click>Edit>Add Driver>DVR/NVR Video Drivers>Axis Camera Station Driver to?add the Axis Camera Station Driver. Right-click the driver>Driver Commands>Start Driver.
  • Right-click the newly added driver and select Edit>Add Controller>Ok to add the Video Controller.
  • Click on the newly added Video Controller>Properties box, enter the following:

IP_Address – enter the IP address of the ACS Server

API Port – enter the Developer API port (default is 50333)

Video Port – enter the Video port 50334

User Name – enter a valid ACS admin user

Password – enter the password for the ACS admin user

  • Save your settings and restart the Axis Camera Station driver.
  • After the driver restarts, you should see a listing of all the cameras below the Video Controller automatically.

IV. Viewing a Camera

  • Right-click on any camera>Live Video. ?
  • Symphony AC Video Manager should now launch and the live video feed will be displayed.